In short. Event power is planned around the event schedule: setup, rehearsal, live operation and dismantling each have different loads and risks. Separate sound, lighting and LED screens from catering and cooling, balance single-phase loads across phases, choose silent sets placed away from the audience, and decide what interruption the show can tolerate. If a power loss would stop the event, provide a second source with a defined transfer arrangement.
Why event power is its own discipline
A failure at a factory is a production loss. A failure at a concert, wedding, exhibition or conference is visible to everyone at once and cannot be repeated. Event loads are also unusual: LED walls, moving lights and amplifiers are non-linear electronic loads; catering and air-cooling are heavy and often single-phase; and the whole installation is built, run and removed within days, often in a public area.
Separate the event into periods
| Period | Typical demand | Planning focus |
|---|---|---|
| Setup | Work lights, tools, rigging motors, testing of systems | Small set or partial supply, safe cable laying |
| Rehearsal | Sound, lighting, screens at near full use | Verify load per phase and voltage quality |
| Live operation | Full show load, catering, cooling, guest facilities | Maximum demand, redundancy, monitoring |
| Dismantling | Work lights, tools, vehicles | Safe de-energisation sequence |
Keep sensitive loads apart
Sound systems pick up noise from switching loads and from earth loops. Put audio on its own generator or feeder, away from catering, cooling and lighting dimmers, and keep a single, clean earth reference. LED walls and moving lights draw current with high harmonic content, which adds in the neutral, so the neutral cable must be at least as large as the phase cables. Allocate catering and single-phase loads deliberately across phases and check the ammeters at rehearsal. Background on harmonic loads is in UPS and non-linear loads.
Redundancy for the show
If losing power would stop the event, decide what interruption is acceptable. A second generator with a changeover switch gives a restart within seconds; a UPS on the sound desk, show control and critical lighting bridges that gap. Synchronised sets sharing the load let one drop out without interruption. Whatever is chosen, test the transfer during rehearsal, not during the show. Transfer equipment is covered on rental ATS.
Noise, placement and public safety
Use acoustic enclosed sets, place them as far from the audience and neighbours as the cable plan allows, and point exhaust and radiator discharge away from people. A catalogue noise figure is measured at a stated distance in open conditions; the level at a boundary depends on distance, reflecting surfaces and the number of sets. Barricade generator and fuel areas, cover or bridge cables across walkways and vehicle routes, and keep extinguishers at each set. See acoustic enclosed generator sets.
Fuel and operation during the event
Fill tanks before the show; refuelling during the event near guests should be avoided. A technician should stay with the sets through live operation, watching load, temperature and fuel, with a clear contact to the production manager for alarms.
A worked load estimate
A load estimate built from vendor figures is far more reliable than a guess from the size of the venue. Consider an outdoor evening event in Hyderabad (illustrative). The sound vendor quotes 40 kW for the main system and monitors, lighting 60 kW of moving heads and LED fixtures, an LED wall 30 kW at full brightness, catering 45 kW including fryers and refrigeration, and air coolers and fans 25 kW. The total is 200 kW. Not every load peaks together, but at a live show most of it does, so a diversity of 0.9 is reasonable, giving 180 kW, or about 225 kVA at 0.8 power factor.
A sensible arrangement is a 125 kVA set dedicated to sound and the LED wall, a 160 kVA set for lighting, and a separate 125 kVA set for catering and cooling, with a changeover so the lighting set can back up the show set if needed. Each set runs at a healthy load, audio is isolated from motors and fryers, and no single failure stops the whole event. A single 320 kVA set would be cheaper, but it would mix sensitive and switching loads and leave no backup at all.
Distribution and cables in public areas
Cable routes at events cross walkways, stage entries and vehicle paths. Use rubber-sheathed flexible cables, cable ramps at every crossing, and distribution boards with 30 mA earth-leakage protection on every circuit that serves sockets or areas the public can reach. Keep distribution boards locked or attended, and label each outgoing feeder with the vendor it supplies. After the event, de-energise in a planned order before vendors start disconnecting, so nobody pulls a live connector. Cable and panel practice is described on temporary distribution panels.
An event power plan on one page (illustrative)
A two-day wedding venue with an evening reception shows how one event divides into periods, each with its own load and its own supply decision.
| Period | Main loads | Demand | Supply |
|---|---|---|---|
| Setup, day one | Work lights, tools, decor lighting tests | About 15 kW | One small set or venue supply |
| Rehearsal and sound check | Sound, stage lighting, LED wall | About 45 kW | Dedicated show set, backup tested here |
| Live evening | Show loads plus catering, air-cooling, general lighting | About 45 kW show and 70 kW general | Show set and separate general set, backup on standby |
| Dismantling | Work lights, tools | About 10 kW | One small set |
For the live evening, the show feeder at 45 kW is about 56 kVA, served by a 62.5 kVA set with a second identical set as backup. The general feeder at 70 kW is about 88 kVA, served by a 125 kVA set so the air-cooling units can restart together after a dip. Keeping the two apart means a catering fault cannot silence the stage.
Balancing single-phase loads
Events are full of single-phase loads: catering equipment, fans, lighting strings and vendor stalls. If they are all connected to one phase, that phase is overloaded while the other two are lightly used, the set’s voltage becomes unbalanced and lights flicker on the heavy phase. Distribution boards are planned with every outgoing circuit allocated to a phase, the current on each phase is measured once the event is live, and circuits are moved if one phase carries much more than the others. A set that is well balanced can carry its full rating; a badly balanced one is limited by its most loaded phase.
Public safety around the sets and cables
- Sets placed behind barriers, away from audience routes, with exhaust directed away from people and tents.
- Cables run overhead or under proper cable ramps where people walk, never loose across paths.
- Every outgoing circuit protected by a residual-current device, with the set and boards earthed.
- Fuel kept in approved containers away from the public and from heat sources, with a fire extinguisher at each set.
- One named person responsible for the power system during the live period, with a radio or phone.
The live-period run sheet
A short run sheet keeps the power team aligned with the show. It lists the start time of each set before doors open, the fuel check before the live period, who switches to backup and how, the order in which loads are restored after any interruption, and the time the show load ends so sets can be run down safely. Running the backup transfer once during rehearsal proves the method and lets the show team know what a transfer looks and sounds like, so nobody panics if it happens live.
Event power enquiry checklist
- Event dates and the hours of setup, rehearsal, live operation and dismantling.
- Vendor power requirements for sound, lighting, LED screens and catering.
- Venue layout with possible set positions and cable routes.
- Noise limits at the boundary or near neighbours.
- Whether the show needs a backup supply and how quickly it must take over.
Placing silent sets for low noise
Noise at the audience or boundary depends more on placement than on the canopy alone. Distance helps most: sound falls noticeably each time the distance doubles. Buildings, walls and parked vehicles between the set and the audience act as barriers, while hard surfaces behind the set reflect sound forward. Pointing the exhaust and radiator outlet away from the audience, keeping canopy doors closed while running and avoiding resonant platforms all reduce what guests hear. A quick check with a sound meter during rehearsal confirms the placement before the live period.
After the event, the readings from the live period, the fuel used and any incidents are written into a short close-out note. The next event at the same venue then starts from measured figures, which usually allows a better-matched set and a cleaner layout.
Common mistakes
- Putting sound on the same feeder as catering and cooling. Hum and dropouts appear in the audio when motors cycle.
- Undersizing the neutral for LED and lighting loads. The neutral cable overheats even though phase currents look normal.
- Testing backup transfer for the first time during the show. A wiring or setting error causes the outage it was meant to prevent.
- Placing sets for convenience near the audience. Noise and exhaust complaints force a relocation at the worst time.
What to send us
Send the event schedule from setup to dismantling, the equipment list from the sound, lighting and screen vendors with their power requirements, catering and cooling loads, a venue plan with possible generator positions, and any noise limits. Send a generator rental enquiry and we will propose sets, distribution and backup.
Questions engineers ask
Why should sound and catering be on separate generators at an event?
Catering and air-cooling equipment switch heavy loads on and off and can fault, while sound, lighting and LED screens are sensitive electronic loads. On a shared supply, every cooler start or catering fault disturbs the show. Separate sets or feeders keep the stage running if the general load trips and stop hum and flicker in the audio and lighting.
How are single-phase loads balanced on an event generator?
Every outgoing circuit is allocated to a phase on the distribution plan so catering, fans, lighting strings and stalls are spread evenly. Once the event is live, the current on each phase is measured and circuits are moved if one phase carries much more than the others, because the most loaded phase limits the whole set.
What size generator do I need for an event?
Add the power requirements from each vendor for the live period, allow for diversity and the starting of cooling equipment, and divide kW by 0.8 for kVA. Then split the total across separate sets or feeders for sound, lighting and general loads, and add a backup for the show feed if an interruption would stop the event.
Do I need a backup generator for an event?
If a power loss would stop the show or create a safety issue in a crowd, yes. The backup needs a defined transfer method, a named person responsible for it and fuel of its own, and the transfer should be tested once during rehearsal so everyone knows what it looks and sounds like.
How quiet are silent generators?
Acoustic enclosures reduce noise considerably, and makers quote levels at a stated distance. The level heard at the audience or boundary depends on distance, surroundings and the number of sets, so placement matters as much as the enclosure. Distance, barriers and outlets pointed away from people make the biggest difference.
Why does my sound system hum on generator power?
Usually because of an earth loop, or because audio shares a supply with switching loads such as catering and cooling. A dedicated feeder or set for audio with a single earth reference normally cures it, and balancing the phases on the general set reduces the disturbance further.
Generators by rating
- Under 15 kVA generators
- 15–50 kVA generators
- 50–125 kVA generators
- 125–250 kVA generators
- 250–500 kVA generators
- 500–1000 kVA generators
- 1000–2000 kVA generators
- 2000 kVA and above generators
Technical content reviewed by D. Srinivas Reddy, Managing Partner and Service Engineer, Reddy Generators. Last updated 19 October 2026.