In short. Reddy Generators sells used (second-hand) and refurbished diesel generators of all major makes, from 15 kVA to 2000 kVA, with the AMF panel, changeover and installation work that make them a complete power system. Makes in stock vary and include Kirloskar, Cummins, Mahindra, Ashok Leyland, Perkins, Caterpillar, Eicher, Escorts, MTU and many more.

Every set is inspected and test-run under load before it is offered, you get the inspection and test record with the machine, and refurbished sets carry a six-month warranty. “Used” and “second-hand” mean the same thing here: a set sold in its existing condition after inspection and testing. “Refurbished” means a set we have rebuilt, either completely or in the parts that needed it, before sale. Stock changes every week, so send your kVA and application and we will tell you what is available.

Used or refurbished: what the words mean on our quotation

Term What has been done What you receive Best for
Used (second-hand) Full inspection, service (oil, filters, coolant, belts, battery check), repairs needed to pass a load test, load-bank test Inspection report, load-test record, hour-meter reading, known history where available Standby duty, budget projects, short-term needs, sites with low running hours
Partially refurbished Used-set work plus rebuilding of the items the inspection found at the end of their life: for example a top overhaul, radiator recore, alternator bearings and AVR, new controller or AMF panel, canopy repair and repaint Everything above plus a list of the parts replaced and the work done, and a six-month warranty Prime or regular standby duty where a new set is not justified
Fully refurbished (rebuilt) Engine major overhaul (liners, pistons, rings, bearings, head work, injectors and pump), alternator rewinding or replacement where needed, new control panel, cooling system overhaul, new wiring, canopy restored Rebuild record with part numbers, load test at 25, 50, 75 and 100%, six-month warranty Long service life at a lower cost than new; sites that need a specific legacy make or model

How we prepare a set before it is offered

  1. Identity and history. Engine and alternator serial numbers, year, hour-meter reading, service history where the previous owner kept it, and the emission-norm status of the set.
  2. Cold start and running inspection. Starting behaviour, oil pressure, coolant temperature, exhaust colour, leaks, vibration, governor and AVR response, and the controller’s alarm log.
  3. Measurements. Compression or blow-by where the engine type allows it, alternator insulation resistance, voltage and frequency at no load and full load, and the condition of batteries, charger and wiring.
  4. Decision: sell as used or refurbish. A set that passes on its own is prepared as a used set. A set with worn items is refurbished, partially or fully, and the work is listed on the quotation so you know exactly what is new.
  5. Load-bank test. Every set runs on our load bank before sale, stepped to full load, with the readings recorded. You are welcome to witness the test at our Pedda Amberpet workshop, by appointment.
  6. Documentation. Inspection report, load-test record, parts list for refurbished sets, and the warranty terms, all before you pay.

What we sell with the set

A generator on its own is not a power system. We supply and install the AMF panel or ATS, the changeover and cabling, earthing, exhaust and acoustic enclosure where needed, and we commission the set on your site across Telangana, Andhra Pradesh and the districts within about 300 km of Hyderabad. The same service engineers who prepared the set service it afterwards under an AMC, which is why we know its history better than anyone.

Warranty and what it covers

Refurbished sets carry a six-month warranty from the date of invoice on the work done and the parts fitted, with service calls attended by our own engineers. Used sets sold as inspected carry the inspection and load-test record as their statement of condition; any defect found during commissioning is corrected before handover. Rubber and plastic parts, consumables, fuel-quality damage, overloading and work by others are outside both. The exact terms are printed on every quotation.

When a used set is the right choice, and when it is not

Selling or trading in your generator

We also buy used generators and take sets in part exchange against a new or refurbished machine. Send the make, kVA, year, hours and photographs of the nameplate and control panel, and we will inspect and make an offer.

What the load-test record shows

StepRecordedWhat it proves
Cold start and no-load runCranking time, oil pressure, voltage, frequencyStarting system and basic health
25 and 50% loadVoltage, frequency, current per phase, exhaust colourGovernor and regulator stability
75% load, sustainedCoolant and oil temperatures, oil pressure, smokeCooling system and engine condition
100% loadAll readings, plus behaviour on the load stepThat the set delivers its rating
Load removedVoltage and speed overshoot, cool-downResponse to a sudden load rejection

The record lists the date, the set’s serial numbers and every reading, so it can be compared with the commissioning test on your site and with later services.

Matching the condition to the duty

DutyUsual choiceReason
Standby behind a reliable grid, few hours a yearUsed, as isLow hours ahead; a tested set serves well
Standby with frequent outagesPartially refurbishedWorn items renewed before regular running
Daily running or prime dutyFully refurbishedRebuilt engine and alternator for long hours
Short project or temporary needRental, or a used set bought back laterAvoids ownership for a short need

Emission stage and used sets

A used set keeps the emission stage it was built and certified to. New sets in the commonly used ratings are now built to the current stage, while older used sets carry earlier stages. Whether an older stage is acceptable depends on where the set will run and what the local pollution control authority requires for it, so the stage is checked against the site before a set is offered, and retrofit emission control is considered where the site needs it.

After the sale

We install the set with its AMF panel or changeover, cabling, earthing and exhaust, commission it on site with a load and transfer test, and service it afterwards across Telangana, Andhra Pradesh and the districts within about 300 km of Hyderabad, with project-based service further afield. The commissioning record joins the inspection report and load-test record, so the set’s history stays complete. See find a generator.

Selling a set back after a project

Where a site needs power for a fixed period, such as a construction project or a plant expansion, buying a used set and selling it back or trading it in at the end can cost less than renting for long periods, while giving the site its own machine for the duration. The set’s condition at the end, shown by its service records and a load test, decides what it is worth when it returns. Discuss the expected period at the start, so the choice between rental and a used set with a planned resale is made on the full numbers.

The first year with a used or refurbished set

What to send us

Tell us the kVA or the load, standby or prime duty, the site location, the makes you prefer, and whether you need the panel, installation and AMC. Use the generator sales enquiry, WhatsApp 98852 01608 with the details, or visit our workshop at Pedda Amberpet, Hyderabad, by appointment, to see the sets in stock. For an independent check of a set you are buying elsewhere, see our used-generator inspection service.

Questions buyers ask

What does a generator load-test record show?

Cranking time and no load readings, then voltage, frequency and phase currents at 25 and 50% load, temperatures, oil pressure and smoke on a sustained 75% run, full load behaviour on the load step, and voltage and speed overshoot when load is removed. It carries the set serial numbers and every reading, for comparison with later tests.

Which condition of used generator suits which duty?

A used set as is suits standby behind a reliable grid with few running hours. A partially refurbished set suits standby with frequent outages. A fully refurbished set suits daily running or prime duty. For a short project or temporary need, rental or a used set bought back later avoids ownership altogether.

Is a used generator the same as a second-hand generator?

Yes. Used and second hand mean the same thing on our quotations: a set sold in its existing condition after inspection, service and a load test, with the inspection report and test record but no warranty. A refurbished set is different: it has been rebuilt and carries a six-month warranty.

What does “refurbished” include?

A refurbished set has been rebuilt, completely or in the parts the inspection found worn, such as a top or major engine overhaul, radiator recore, alternator bearings or rewinding, regulator, controller, wiring and canopy repair. It comes with a list of the work and parts, a full load test and a six-month warranty.

Can I see the set run before I buy?

Yes. Viewing at our Pedda Amberpet workshop is by appointment, and you can witness the load bank test of the exact set you are buying, with voltage, frequency, temperatures and oil pressure recorded at each load step on the test sheet that comes with the set.

What warranty does a refurbished generator carry?

Six months. It excludes rubber and plastic parts, consumables, damage from poor fuel quality and damage from overloading. Used sets sold as is carry no warranty but come with the inspection report and the load test record, so you know the condition you are buying.

Which makes and sizes are available?

Sets of all major makes from 15 kVA to 2000 kVA pass through the workshop, and the stock changes every week. Send the rating you need, the duty and the site location, and we will tell you what is available now or arriving soon, with the inspection and test records for each set.

Can a used set meet current emission rules?

A used set keeps the emission stage it was certified to, so whether it is acceptable depends on where it will run and what the local pollution control authority requires. We check the stage against the site before offering a set, and retrofit emission control can be considered where the site requires it.

Do you buy used generators?

Yes. We buy used generators outright and take sets in part exchange against a replacement. Send photographs of the nameplates, the hour meter reading, service records if any and a short video of the set running for an indication, confirmed after we see the set run.

Browse used sets by rating

Buyer guides for the most-asked sizes: used 125 kVA, used 250 kVA and used 500 kVA — and how used sets are valued.

Generators by rating

Technical content reviewed by D. Srinivas Reddy, Managing Partner and Service Engineer, Reddy Generators. Last updated 1 November 2026.