In short. A diesel generator burns fuel in proportion to the real power it delivers in kW, not its kVA rating. At full load a modern set uses about 0.25 to 0.33 litres per kWh, so a 125 kVA set (100 kW) burns about 27 to 30 litres an hour, a 250 kVA set about 54 to 57, a 500 kVA set about 100 to 110 and a 1000 kVA set about 200 to 210, from current makers’ published data. At light load it burns less per hour but more per kWh. The chart below gives indicative litres per hour at 25, 50, 75 and 100% load for every common rating from 7.5 to 3000 kVA.
Who this page is for: For owners, facility managers and buyers who need a quick, reliable figure for diesel use, tank size, refuelling and running cost at a given generator rating and load.
Key facts
- Fuel use follows real power (kW), not kVA: power factor changes the current, and barely changes the fuel.
- Full-load consumption: about 0.25 to 0.33 litres per kWh, better on larger engines.
- At 25% load the same set uses about 25 to 40% more fuel per kWh than at full load.
- Near full load, one litre of diesel gives a generator set about 3.0 to 4.0 kWh of electricity; less at light load.
- From a data sheet: litres per hour = g/kWh × kW ÷ (1000 × 0.84).
- Figures are indicative within about ±10 to 15%; the set’s own data sheet governs.
Quick answers: diesel per hour at full and 75% load
- 62.5 kVA DG: about 15 to 16 L/h at full load, 11.5 to 12.5 L/h at 75%
- 82.5 kVA DG: about 20 L/h at full load, 16 L/h at 75%
- 125 kVA DG: about 27 to 30 L/h at full load, 21 to 23 L/h at 75%
- 160 kVA DG: about 36 L/h at full load, 28 L/h at 75%
- 250 kVA DG: about 54 to 57 L/h at full load, 42 to 46 L/h at 75%
- 320 kVA DG: about 69 to 71 L/h at full load, 53 to 55 L/h at 75%
- 500 kVA DG: about 100 to 110 L/h at full load, 77 to 83 L/h at 75%
- 750 kVA DG: about 162 L/h at full load, 124 L/h at 75%
- 1000 kVA DG: about 200 to 210 L/h at full load, 150 to 160 L/h at 75%
- 1500 kVA DG: about 300 L/h at full load, 231 to 234 L/h at 75%
Ranges are from current makers’ published data for modern diesel sets at 0.8 power factor; single figures are the chart values. Find any rating in the full chart below.
DG fuel consumption chart, 7.5 to 3000 kVA
Litres per hour at four loads, for a modern diesel set rated at 0.8 power factor. Click a rating to link straight to its row.
| Rating (kVA) | kW at 0.8 PF | 25% load (L/h) | 50% load (L/h) | 75% load (L/h) | 100% load (L/h) |
|---|---|---|---|---|---|
| 7.5 | 6 | 0.7 | 1.1 | 1.5 | 1.9 |
| 10 | 8 | 0.9 | 1.4 | 2.0 | 2.6 |
| 15 | 12 | 1.3 | 2.2 | 3.0 | 3.8 |
| 20 | 16 | 1.8 | 2.9 | 4.0 | 5.1 |
| 25 | 20 | 2.2 | 3.6 | 5.0 | 6.4 |
| 30 | 24 | 2.6 | 4.3 | 5.9 | 7.7 |
| 40 | 32 | 3.2 | 5.4 | 7.7 | 9.9 |
| 45 | 36 | 3.6 | 6.1 | 8.6 | 11.2 |
| 50 | 40 | 4.0 | 6.8 | 9.6 | 12.4 |
| 62.5 | 50 | 5.0 | 8.5 | 12.0 | 15.5 |
| 75 | 60 | 6.0 | 10.2 | 14.4 | 18.6 |
| 82.5 | 66 | 6.6 | 11.2 | 15.8 | 20 |
| 100 | 80 | 8.0 | 13.6 | 19.2 | 25 |
| 125 | 100 | 9.5 | 15.5 | 22 | 28 |
| 140 | 112 | 10.6 | 17.4 | 24 | 31 |
| 160 | 128 | 12.2 | 19.8 | 28 | 36 |
| 180 | 144 | 13.7 | 22 | 31 | 40 |
| 200 | 160 | 15.2 | 25 | 35 | 45 |
| 250 | 200 | 19.0 | 31 | 44 | 56 |
| 275 | 220 | 19.3 | 32 | 45 | 59 |
| 320 | 256 | 22 | 38 | 53 | 69 |
| 380 | 304 | 27 | 45 | 63 | 82 |
| 400 | 320 | 28 | 47 | 66 | 86 |
| 450 | 360 | 32 | 53 | 74 | 97 |
| 500 | 400 | 35 | 59 | 83 | 108 |
| 600 | 480 | 42 | 71 | 99 | 130 |
| 625 | 500 | 44 | 74 | 103 | 135 |
| 650 | 520 | 46 | 77 | 107 | 140 |
| 750 | 600 | 53 | 89 | 124 | 162 |
| 1000 | 800 | 64 | 112 | 156 | 200 |
| 1010 | 808 | 65 | 113 | 158 | 202 |
| 1250 | 1000 | 80 | 140 | 195 | 250 |
| 1500 | 1200 | 96 | 168 | 234 | 300 |
| 1750 | 1400 | 112 | 196 | 273 | 350 |
| 2000 | 1600 | 128 | 224 | 312 | 400 |
| 2250 | 1800 | 144 | 252 | 351 | 450 |
| 2500 | 2000 | 160 | 280 | 390 | 500 |
| 3000 | 2400 | 192 | 336 | 468 | 600 |
Need the current or the breaker for a rating? See the full-load current chart, the breaker, changeover and cable size chart and the generator size chart.
How the chart is worked out
The litres-per-kWh figures behind the chart are typical of modern diesel sets and vary with size, because larger engines are more efficient:
| Rating band | 25% load | 50% load | 75% load | 100% load |
|---|---|---|---|---|
| Up to 30 kVA | 0.44 | 0.36 | 0.33 | 0.32 |
| 40 to 100 kVA | 0.40 | 0.34 | 0.32 | 0.31 |
| 125 to 250 kVA | 0.38 | 0.31 | 0.29 | 0.28 |
| 275 to 750 kVA | 0.35 | 0.295 | 0.275 | 0.27 |
| 1000 kVA and above | 0.32 | 0.28 | 0.26 | 0.25 |
Engine data sheets often state specific fuel consumption in grams per kWh. To convert, divide by the density of diesel, about 0.84 kg per litre:
Why fuel follows kW, not kVA
The engine supplies only real power. A 500 kVA set carrying 400 kVA at 0.8 power factor and the same set carrying 320 kVA at unity power factor both deliver 320 kW, and burn almost the same diesel. Poor power factor raises the current and the alternator’s heating, not the fuel. So to estimate consumption, start from the kW the site actually draws, which a clamp-on power meter or the generator controller shows, not from the set’s rating. For the conversion, see kW and kVA.
Light load costs more per unit
An engine has fixed friction and pumping losses that it pays at any load. At 25% load those losses are spread over a quarter of the output, so each kWh costs about 25 to 40% more fuel than at full load. Long running below about 30% load also leads to wet stacking, glazed liners and carbon build-up. If a set spends most of its life lightly loaded, a smaller set, or two sets that share the load, will save fuel. See light-load running and wet stacking.
Do not run a diesel set for long periods below about 30% load to save fuel. The fuel saving is small and the engine damage is real. Plan regular runs at higher load or a load-bank test instead.
Worked examples (illustrative)
A 125 kVA set in an office during a 10-hour outage
The office draws about 60 kW, which is 60% of the set’s 100 kW. From the chart, 50% load is about 15.5 L/h and 75% about 22 L/h, so about 18 L/h at 60%. Ten hours needs about 180 litres. A 250-litre base tank with about 90% usable holds about 225 litres, enough for about 12 hours at this load.
A 250 kVA set on a construction site
The site runs at about 75% load for 10 hours a day, six days a week. The chart gives about 44 L/h, within the 42 to 46 of makers’ data, so about 440 litres a day and 2640 litres a week. The fuel plan needs a bowser or a bulk tank with a refuelling schedule, not just the base tank. See the fuel tank sizing guide.
Running cost per kWh
Multiply the litres per kWh at your load by your diesel price per litre to get the fuel cost of each unit generated. At 75% load on a 500 kVA set that is about 0.275 litres per kWh. Add maintenance and wear for the full cost. Your own figures can be worked through in the fuel runtime calculator.
How the chart compares with makers’ data
The litres-per-kWh figures behind the chart were set against current published data sheets from several makers, at the ratings where that data is available. The chart value is the single planning figure; the makers’ column shows the spread between makes at the same rating.
| Rating | Chart, 75% load | Makers’ data, 75% load | Chart, full load | Makers’ data, full load |
|---|---|---|---|---|
| 20 kVA | 4.0 L/h | 3.9 to 4.1 L/h | 5.1 L/h | 5.1 to 5.3 L/h |
| 62.5 kVA | 12.0 L/h | 11.5 to 12.3 L/h | 15.5 L/h | 15.3 to 16.3 L/h |
| 125 kVA | 22 L/h | 21 to 23 L/h | 28 L/h | 27 to 30 L/h |
| 250 kVA | 44 L/h | 42 to 46 L/h | 56 L/h | 54 to 57 L/h |
| 500 kVA | 83 L/h | 77 to 83 L/h | 108 L/h | 100 to 110 L/h |
| 1500 kVA | 234 L/h | About 231 L/h | 300 L/h | About 302 L/h |
Across the ratings checked, every chart value sits within about 5% of the makers’ figures, and most sit inside the published range. Small sets use noticeably more diesel for each kWh than large ones, which is why the chart works in size bands rather than one factor for every rating.
What makes real consumption differ from the chart
| Factor | Effect |
|---|---|
| Engine size, design and emission stage | Real spread between makes at the same rating is about 8%: current data sheets for 1000 kVA and above put full-load consumption between 0.248 and 0.267 litres per kWh. Older mechanical engines sit above that band |
| Hot ambient air and altitude | Less air per stroke; consumption rises and the set may need derating |
| Condition | Worn injectors, dirty air filters and low compression can add 10% or more |
| Load pattern | Frequent large steps and light-load running increase fuel per kWh |
| Fuel quality and leaks | Water, dirt or leaks show up as higher apparent consumption |
Measuring your set’s real consumption
- Fill the tank to a marked level, or note the reading of a calibrated gauge.
- Note the running-hours meter and the kWh meter.
- Run for several hours, at least three or four, at a steady, typical load.
- Refill to the same mark, or back to the same gauge reading, and record the litres added.
- Divide litres by hours for litres per hour, and litres by kWh for litres per kWh.
Compare the result with the chart. A set that uses more than about 15% above its own data sheet, or about 20% above the chart, at the same load needs checking. See diesel generator fuel consumption for the full method.
Fuel log worksheet
One month of weekly entries from the same cold storage warehouse, on a single 500 kVA set rated 400 kW. The chart above gives the figures a healthy set should produce at each loading; this log is one site proving that curve on its own machine, which is what turns a published table into something a manager can plan against.
| Date | Hours run | Average load (kW) | kWh generated | Litres added | Litres per kWh |
|---|---|---|---|---|---|
| Week 1 | 22 | 120 (30% of rating) | 2640 | 933 | 0.353 |
| Week 2 | 26 | 200 (50%) | 5200 | 1560 | 0.300 |
| Week 3 | 31 | 300 (75%) | 9300 | 2542 | 0.273 |
| Week 4 | 28 | 360 (90%) | 10,080 | 2666 | 0.264 |
| Month | 107 | — | 27,220 | 7701 | 0.283 |
One machine, one month, and the last column runs from 0.264 to 0.353 — a third more fuel for every unit of electricity in week one than in week four. Nothing was wrong with the set in week one. It was simply running at 30% of its rating while the warehouse was half empty between contracts, and a diesel engine spreads its fixed losses over whatever output it happens to be producing. The curve on this page predicts exactly this shape, and here it is in a site’s own fuel book.
Week one is also the week that looks best on a fuel bill. It burned 933 litres against week four’s 2666, and about 42 litres an hour against 95. Anyone reading the litres column alone would call it the efficient week, and anyone reading the last column would call it the expensive one. Both are looking at the same four numbers; only one of them is answering the question the business actually has, which is what each unit of refrigeration cost.
Every row closes on itself, and that is the first thing to check before reading anything into the pattern. Hours times average load gives the kilowatt-hours — 22 hours at 120 kW is 2640 — and litres divided by kilowatt-hours gives the last column. A row where those two do not hold is a transcription error, not a finding, and the month row is the sum of the four weeks above it rather than a separate measurement.
The monthly figure of 0.283 is the one worth carrying forward, and it is worth noticing that it is not the average of the four weekly figures. It is weighted by the energy each week produced, so the two heavily loaded weeks dominate it; a straight average of the column would give 0.298 and overstate the month by about 5%. Fuel per unit is always weighted by output, never averaged across periods, and that is the arithmetic mistake most likely to be made on a sheet like this.
What the log is for, once a few months of it exist, is spotting the thing that does not fit. A week at 0.353 is unremarkable at 30% load and would be alarming at 90%. A month whose figure drifts upward while the loads stay the same points at injectors, air filters, a turbo or fuel quality, in roughly that order. Without the third column there is no way to tell a light month from a sick engine, which is why the average load is recorded even though the controller does not always make it easy to read.
One operational conclusion came out of this month on this site. Week one at 30% was carried by the 500 kVA set because that is the set that was there; at that load the site would have been better served by a smaller machine or by shifting the cold store’s defrost cycles into the loaded hours. Neither change was free, but the log is what made the question askable, and a site that cannot see week one in its own records never asks it.
Questions owners ask
How accurate is a generator fuel consumption chart?
A good chart is a planning figure, not a promise. The values on this page sit within about 5% of current makers published data at the ratings checked, while makes differ from one another by about 8% at the same rating. Engine condition, ambient heat and the load pattern add more, so a measured fuel log on site is the final word.
How much diesel does a 250 kVA generator use per hour?
About 54 to 57 litres per hour at full load (200 kW), about 42 to 46 at 75% load and about 31 at half load, from current makers published data for modern sets. The chart on this page uses 56 and 44 at those first two loads. The data sheet of the actual set governs, and a fuel log confirms it on site.
How much diesel does a 125 kVA generator use per hour?
About 27 to 30 litres per hour at full load (100 kW), about 21 to 23 at 75% load and about 15 to 16 at half load, from current makers published data for modern sets. The chart on this page uses 28, 22 and 15.5. The data sheet of the actual set governs, and a measured fuel log on site confirms it.
How much diesel does a 500 kVA generator use per hour?
About 100 to 110 litres per hour at full load (400 kW), about 77 to 83 at 75% load and about 59 at half load, from current makers published data for modern sets. The chart on this page uses 108, 83 and 59. At this size a few percent of extra consumption is a large quantity of diesel over a year, so a fuel log is worth keeping.
How much diesel does a 1000 kVA generator use per hour?
About 200 to 210 litres per hour at full load (800 kW), about 150 to 160 at 75% load and about 112 at half load, depending on the engine. Larger engines are the most efficient per kWh, at about 0.25 litres per kWh near full load, and like every engine they use more fuel for each unit delivered at light load.
How many units (kWh) does one litre of diesel produce in a generator?
About 3.0 to 4.0 kWh per litre at good loading: about 3.0 to 3.2 on small sets and about 4.0 on sets of 1000 kVA and above near full load. At light load it falls, to well below 3 on small sets at a quarter load, because the fixed losses of the engine are spread over less output.
Does power factor change fuel consumption?
Hardly. Fuel follows the real power in kW. A poor power factor raises the current and the heating of the alternator, but not the fuel use of the engine for the same kW. To estimate diesel use, start from the kW the site actually draws, which a power meter or the generator controller shows, rather than from the kVA rating of the set.
How do I convert g/kWh on a data sheet to litres per hour?
Multiply the g/kWh figure by the kW load and divide by 840, the grams in a litre of diesel. For example, 210 g/kWh at 400 kW is about 100 litres per hour. Use the g/kWh figure for the load you expect, because data sheets give a different value at each load step and it rises as the load falls.
Evidence note. Chart values are calculated from the litres-per-kWh figures shown, which were set against current makers’ published data, and rounded. Actual consumption depends on the engine, its condition and the site; use the set’s data sheet and a measured fuel log for final planning.
Generators by rating
- Under 15 kVA generators
- 15–50 kVA generators
- 50–125 kVA generators
- 125–250 kVA generators
- 250–500 kVA generators
- 500–1000 kVA generators
- 1000–2000 kVA generators
- 2000 kVA and above generators
Technical content reviewed by D. Srinivas Reddy, Managing Partner and Service Engineer, Reddy Generators. Last updated 8 November 2026.