62.5 kVA generators for a national life insurer’s branch offices in Hyderabad, Secunderabad, Vijayawada and Khammam, 2008–2014

62.5 kVA acoustic generators rented from 2008 to 2014 to a national life insurer’s branch offices in Hyderabad, Secunderabad, Vijayawada and Khammam.

In short. From April 2008, Reddy Generators rented 62.5 kVA acoustic diesel generators to the branch offices of a national life insurance company, starting with its Hyderabad and Secunderabad branches and Vijayawada in 2008, then adding a Hyderabad (Dilsukhnagar) branch in September 2009 and Khammam. Each set was a new acoustic unit with a standard panel and a monthly engineer’s visit. The contract was renewed year by year and ran until 2014, about six years, under one supplier across three cities.

ClientA national life insurance company (name withheld)
SitesBranch offices in Hyderabad, Secunderabad, Vijayawada, Hyderabad (Dilsukhnagar) and Khammam
Hyderabad and SecunderabadLetters of indent dated 18 April 2008; contract from 1 April 2008
VijayawadaLetter of indent dated 2 May 2008; annual contract from 1 April 2008
HyderabadPurchase order dated 22 September 2009 for installation materials and labour
Duration2008 to 2014 (about six years), renewed annually
EquipmentNew 62.5 kVA acoustic diesel sets (Kirloskar, Mahindra or Tata engines) with standard panel
ServiceMonthly engineer’s visit; cabling, foundation and transport as required

The requirement

Insurance branches serve walk-in customers and process policies on networked systems, so a power cut stops business. The client’s facilities team in Bangalore needed dependable backup at branches across undivided Andhra Pradesh (today Telangana and Andhra Pradesh), specified to one standard and run by a single accountable supplier instead of separate vendors in each town.

One standard across three cities

The client’s specification called for a new acoustic 62.5 kVA set at each branch, a size that suits a typical office load of lighting, computers, servers and air conditioning. The contract was written as an annual rental with a one-month notice period, a monthly engineer’s visit, and diesel, cabling, foundation and transport charged at actual cost, which kept costs transparent for the client. Hyderabad, Secunderabad and Vijayawada started in 2008; a Hyderabad (Dilsukhnagar) branch followed in September 2009 with Reddy Generators providing the installation materials and labour, and Khammam was added under the same arrangement.

What one standard across several cities means in practice

When a facilities team in one city manages branches in several others, a common standard is what makes the arrangement workable. Every branch receives the same type of set, installed the same way, serviced on the same schedule and reported in the same format. The team can then compare branches, budget with confidence and deal with one supplier rather than several.

ElementWhat the standard fixes (illustrative)
SetRating, acoustic enclosure, panel type and fuel tank size
InstallationFoundation, cable type and route, earthing and connection to the branch board
ServiceVisit frequency, checks carried out and readings recorded
ReportingOne format for every branch, sent on a fixed cycle
RenewalAnnual review of performance and any changes needed

Worked example: a 62.5 kVA set for an insurance branch (illustrative)

A 62.5 kVA set gives 50 kW at 0.8 power factor. An insurance branch with counters, a server and network, printers and copiers, lighting and air conditioning might draw about 30 kW on a busy afternoon. That leaves comfortable headroom for air-conditioning restarts after a power cut and for printers and copiers, which draw short surges when they warm up. The margin also lets the branch grow without a change of set, provided the load is reviewed each year.

What a monthly engineer visit covers

A monthly visit suits sets that run few hours, because it catches slow problems such as weak batteries or water in fuel before an outage exposes them.

Using the annual renewal well

A contract renewed each year gives both sides a natural moment to review. The review looks at hours run in each branch, faults and how they were handled, any changes in branch load, and whether any branch has moved or is about to. Small adjustments, such as moving a set when a branch relocates or changing the visit pattern for a branch with frequent outages, keep the arrangement matched to the business.

Serving branches in different cities

Branches several hours apart need planned service routes, spares held where they are most likely to be needed, and clear contacts in each branch. Visits are grouped so that each trip covers the work due in that city, and breakdown arrangements for each location are agreed at the start rather than worked out during an outage.

Worked example: fuel at a branch (illustrative)

At about 30 kW and roughly 0.29 litres per kWh, a 62.5 kVA set uses close to 9 litres an hour. A full working day of outage, around nine hours, uses about 80 litres. Keeping enough fuel in the base tank for at least one full working day, and recording the level after every run, keeps each branch ready.

Branch staff and the generator

Branch staff are not engineers, but they are the first to notice a problem. A short briefing at each branch on what to do when the power fails, who to call, how to recognise warning signs such as unusual noise or smoke, and where the emergency stop is, makes a large difference. A notice beside the set with the contact numbers keeps that knowledge in place as staff change.

Lessons for multi-branch organisations

Multi-branch backup works best when it is treated as one system: one specification, one service routine, one reporting format and one accountable supplier, reviewed every year. That approach lets a facilities team in another city manage many branches with confidence, and gives each branch dependable power without needing its own technical staff.

Installation details at each branch

A standard installation removes guesswork from every new branch. The set stands on a level foundation with drainage, positioned where it can be refuelled and serviced and where its exhaust does not reach windows or neighbours. An armoured cable runs from the set to a changeover arrangement at the branch board, sized for the full set rating. The set frame and neutral are earthed and tested, and the cable route is protected from vehicles and damage. Recording these details once, with photographs, makes later visits and any relocation straightforward.

Acoustic sets in branch locations

Branches are usually in commercial streets or office buildings, close to neighbours. Acoustic enclosures keep noise to an acceptable level, but only if doors are kept shut, seals are intact and the set is not placed against a hard wall that reflects sound towards occupied spaces. These points are checked at each monthly visit.

Comparing branches with the same data

MeasureWhat it reveals
Hours run per month at each branchWhich locations suffer the most outages
Fuel used per hourSets running unusually heavy or with a fault
Faults recordedRecurring problems at particular sites
Starting battery conditionSets at risk of failing to start

Because every branch reports the same measures, differences stand out at once and can be acted on before they affect customers.

Earthing checks across branches

Earth resistance changes with soil moisture, so a reading that was good at installation can rise in a dry summer. Testing earthing at each branch at least yearly, preferably in the dry season, and recording the values in the common format keeps fault protection effective everywhere.

When a branch closes or moves

Over several years, some branches will close or relocate. A clear procedure for disconnecting, removing and reinstalling a set, agreed at the start, means a move is a planned task rather than a disruption.

Protecting the branch server and network

Policy processing depends on the branch server and its network link. These sit behind a UPS that bridges the seconds before the set takes load. The UPS is sized for that bridge with margin for a failed first start, its input settings allow for normal generator frequency movement, and its batteries are checked alongside the generator, so the two work as one system rather than as separate pieces of equipment.

Seasonal precautions in different cities

Branches in different cities face different weather. Hot, dry months raise air temperatures around sets and clog filters with dust; the monsoon brings flooding risk to ground-level and basement locations, especially in low-lying areas near rivers. The monthly visits before each season are used to clean radiators, check drainage around the foundation and seal cable joints, so every branch enters the season ready.

A short pre-season note for each branch, filed with the monthly reports, shows the facilities team that every location was checked.

Outcome and limits

The branches were supplied from 2008 until 2014, with the contract renewed year by year. This record is based on the client’s letters of indent for Hyderabad, Secunderabad and Vijayawada, its purchase order for the Dilsukhnagar branch, and Reddy Generators’ contract records for Khammam; operating logs are not published.

Questions engineers ask about this project

What should a common generator standard for many branches include?

The set rating, enclosure, panel and tank size; the installation method, cable, earthing and connection; the service frequency and checks; one reporting format; and an annual renewal review. A common standard lets a facilities team compare branches, budget with confidence and work with one supplier.

What does a monthly generator visit at a branch cover?

A visual check, oil, coolant and fuel levels, belts and hoses, starting battery and charger, a test run with readings, cleaning of filters and radiator, service at the hour or six-month limit and a short report for the branch and facilities team. Monthly visits catch slow problems early.

How is a 62.5 kVA set checked for an office branch?

Compare the busy-afternoon load with the 50 kW the set gives at 0.8 power factor. In the illustrative branch, about 30 kW leaves room for air-conditioning restarts and printer surges, and for some growth, provided the load is reviewed at each annual renewal. Branch growth is tracked in the yearly review.

Why compare generator data across branches?

Because the same measures from every branch, such as hours run, fuel per hour, faults and battery condition, make differences stand out. A branch with more outages, higher fuel use or recurring faults can be acted on before customers are affected. It also helps plan spares and service routes.

Can one supplier handle generators for branches in different cities?

Yes. Here one contractor supplied and maintained 62.5 kVA sets at branches in Hyderabad, Secunderabad, Vijayawada and Khammam, so the client had one contract, one standard and one point of contact. Service records were kept for each branch, so the client could see the condition and running history of every set at any time.

What size generator does a branch office need?

For a typical branch with lighting, computers, servers and air conditioning, 62.5 kVA is a common size. The right rating comes from the branch’s actual load list and its largest air-conditioning or lift motor. A short load survey at peak time confirms the figure, and staggered restarts of air-conditioners after a transfer keep the starting demand within the set capacity.

What is included in a monthly office generator rental?

On this contract: a new acoustic set with a standard panel, a monthly engineer’s visit, cabling, foundation, transport and loading as required, with diesel billed at actual cost and a one-month notice period. Terms for each contract are agreed in writing at the start, so both sides know what is included.

Engineering record reviewed by D. Srinivas Reddy, Managing Partner and Service Engineer, Reddy Generators. Client name withheld. Sources: client letters of indent dated 18 April 2008 and 2 May 2008, purchase order dated 22 September 2009 and company records. Last reviewed: 20 October 2026.