Reddy GeneratorsREDDY GENERATORSThe dependable power professionals

LV Switchboards, PCC, MCC and Distribution Architecture Guide

How low-voltage switchboards, power control centres and motor control centres are arranged, with form of separation, busbar ratings, incomer and feeder design, and what to specify.

In short. A PCC takes power from the source and distributes it to large feeders; an MCC feeds and controls motors; distribution boards serve smaller loads. Their design sets fault withstand, safety during maintenance and how easily the system can grow.

Roles

AssemblyTypical role
PCCIncomers, bus coupler, large outgoing feeders
MCCMotor starters, drives, control
PDB or sub-distributionBranch circuits to areas
Generator panelGenerator breaker, metering, protection

Key specification points

Distribution layouts

The choice follows the redundancy goal. See N+1.

Generator and ATS integration

Decide whether the generator feeds the whole PCC or an essential bus. Include interlocks to prevent paralleling of unsynchronised sources. See interlocking and transfer logic.

Selection steps

  1. Prepare the load schedule and the single-line diagram.
  2. Find the fault level at the board.
  3. Choose busbar and device ratings with margin.
  4. Choose the form of separation and layout.
  5. Specify type-test certificates and routine tests.
  6. Plan access and clearances in the room.

Illustrative example

A plant needs a 1,600 A PCC with two incomers (grid and generator), a coupler and eight outgoing feeders. With a fault level of 40 kA, the board is specified for a higher short-time withstand, with withdrawable breakers and a higher form of separation for the essential section, so that a feeder can be serviced without losing the whole board.

Reading the architecture of an LV system

Incomer (transformer or generator) → main busbar in the PCC → outgoing feeders → MCCs and distribution boards → final circuits. The PCC (power control centre) holds the main breakers and large feeders. MCCs (motor control centres) group starters. Distribution boards serve lighting and small power.

Form of separation

FormLevel of internal separationEffect on maintenance
Form 1No internal separationWhole board usually isolated
Form 2Busbars separated from functional unitsSome live parts remain during work
Form 3Units also separated from each otherIndividual units can be worked on more safely
Form 4Terminals also separatedHighest practical safety for withdrawable units

Higher forms cost more but allow maintenance without shutting the whole board, valuable in continuous-process plants.

Architecture choices

  1. Single bus with one incomer: simple, a single point of failure.
  2. Bus section with bus coupler: two incomers, either can feed both sides.
  3. Separate generator bus: critical loads on an emergency board.
  4. Dual-fed boards with automatic transfer for critical loads.

Ratings to verify

Space and future growth

Allow spare feeders and space to extend the board. Retrofitting a fully packed switchboard is expensive and often needs a shutdown.

Illustrative example

A plant puts its fire pumps, lifts and controls on an emergency board fed from the generator through an ATS, while production loads on the main board are shed during generator operation. This keeps the generator within its capacity and the critical services protected.

Common mistakes

What to send us

Send the load list and single-line diagram. Send your application details.

Questions engineers ask

What is the difference between PCC and MCC?

A PCC distributes power from sources to large feeders. An MCC houses motor starters and controls.

Is withdrawable always better?

It improves maintainability and safety but costs more. Use it where uptime matters.

How much spare capacity should I allow?

Set by growth plans. Typical practice leaves spare spaces and bus capacity for future feeders.

Does the board need a type test?

Assemblies should be supplied with evidence of design verification to the applicable standard.

This guide gives general principles. Specifications should follow the applicable standards.