Reddy GeneratorsREDDY GENERATORSThe dependable power professionals

OT Network Architecture for Critical Power

How to design operational-technology networks for power systems: zones and conduits, segmentation, redundancy, remote access, patching, logging and resilience when IT or internet links fail.

In short. Modern generators, UPS and ATS controllers are networked. That brings visibility and also risk. An OT network should be segmented, redundant where needed, tightly controlled for remote access and designed so that local power control works even when the wider network is down or under attack.

Zone model

ZoneContentsRule
Control zonePLCs, relays, generator controllers, ATSMost protected; minimal access
Supervisory zoneSCADA servers, historian, HMIRestricted flows to control zone
DMZData brokers, remote access gatewaysOnly point of contact with IT and outside
Enterprise ITBusiness systemsNo direct access to control

Design principles

Specific risks for power equipment

Resilience to loss of network

Devices must keep operating in local automatic mode if the network is lost. Test by unplugging the supervisory network and confirming transfers, sharing and protection still work. See degraded modes.

Recovery

Have a plan to restore controllers and SCADA from backup, with known good configuration and a cleanroom approach if compromise is suspected.

Illustrative example

A site’s generator controllers were visible from the corporate network with default passwords. Remediation separates them into a control VLAN, moves remote access to a gateway with multi-factor authentication, and disables direct internet routes. A test removes the supervisory link; generators continue to share load and transfer correctly.

Why OT networks need their own design

The network that carries breaker status and control commands is part of the power system. Its failure or compromise can affect supply. It must be engineered for availability and security, not just connectivity.

ZoneContentsRule
Field/control zoneRelays, controllers, PLCsIsolated from office networks
Supervisory zoneSCADA servers, HMIControlled access
DMZHistorian mirror, remote access gatewayNo direct path from enterprise to control
EnterpriseBusiness ITNever directly connected to field

Availability design

  1. Ring topology or parallel redundancy protocols for control-level networks.
  2. Industrial-grade managed switches with redundant power.
  3. Separate networks for critical traffic where needed.
  4. Battery-backed network equipment.

Security basics

Standards for method

IEC 62443 provides a recognised framework for industrial security. Apply it proportionately to site criticality.

See SCADA architecture and degraded modes.

The master engineering question

If an attacker or a fault took control of the network tomorrow, could the plant still operate safely and could we find out what happened?

What to send us

Send network diagrams and device lists. Send your application details.

Questions engineers ask

Is air-gapping realistic?

Rarely complete; plan for controlled connections instead.

Who is responsible, IT or OT?

Both, with clear roles and shared incident plans.

Can vendors connect remotely?

Yes, via controlled, logged, time-limited sessions.

Which standards guide this?

Industrial security frameworks such as IEC 62443 are widely used.

This guide gives general principles. Engage qualified security professionals for design.