DG Emissions Retrofit: RECD vs Dual Fuel vs Replacement

A decision comparison for an existing diesel generator: RECD retrofit, dual-fuel conversion or replacement. Criteria, trade-offs, duty profiles that favour each and the data needed to choose.

In short. RECD targets exhaust pollutants on the existing engine. Dual fuel changes the fuel and part of the combustion. Replacement gives a new engine under current rules. Duty profile, engine condition, fuel access and regulation decide which is best.

Comparison

CriterionRECDDual fuelReplacement
Main benefitLower exhaust pollutantsLower diesel use, possible emission changeModern engine and compliance
Best forSound engines, steady or loaded dutyHigh run-hours, gas availableOld, worn or non-compliant sets
LimitationsTemperature, back-pressure, maintenanceGas supply, safety, load limitsCapital cost, downtime
ApprovalConfirm routeConfirm routeStandard for new sets

See each: RECD, dual fuel, replacement decision.

Decision logic

  1. What does the rule require for this set and place?
  2. What is the engine’s condition and remaining life?
  3. How many hours per year, and at what load?
  4. Is gas available and reliable?
  5. What is the total cost over the remaining life?

Typical outcomes (illustrative)

Illustrative example

A school has a 15-year-old set used 80 hours a year. Replacement is costly for such low use; a retrofit or restricted operation may be enough, subject to local rules. A factory with 4,000 hours a year looks at dual fuel or replacement instead.

Illustrative scenarios

ScenarioLikely best routeWhy
Hospital standby set, 60 hours a year, sound engineRECD or documented restricted use; consider storageFew hours make fuel savings small
Factory prime power, 5,000 hours a year, gas pipeline nearbyDual fuel or gas setFuel savings accumulate
Twenty-year-old set, heavy oil use, frequent repairsReplacementPoor base for investment
Data centre with strict uptime, rules tighteningNew compliant sets plus storageReliability and compliance together

A lifetime cost sketch

Lifetime cost = capital + installation + consumables + fuel + maintenance + downtime risk − residual value

Fill each term over the same remaining life for each option. Fuel dominates for high-hours duty; capital and compliance dominate for standby.

Risks to weigh

Hybrid answers

Options can combine: a new compliant set plus storage; a retrofit now with replacement planned in a few years; dual fuel on the busiest set and documentation only on the standby sets. See hybrid modernisation.

Making the decision traceable

  1. State the objective: compliance, cost, reliability, carbon.
  2. List the options and the data behind each.
  3. Score and discuss.
  4. Record the decision and review date.

This record helps if rules change later or if the decision is questioned.

The master engineering question

Which option meets the rule at the lowest lifetime cost and risk for this duty?

What to send us

Send engine, hours, location and fuel options. Send your application details.

Questions engineers ask

Which is cheapest?

Depends on duty and life; calculate for the case.

Can I combine options?

Sometimes, subject to engineering and approvals.

What if rules change?

Choose with some flexibility.

Who decides compliance?

The relevant authority.

General guidance only. Confirm regulations.